Oil Fired Incinerator

  • Description
  • Features
  • Specification
  • Optional Attachments
  • Application
  • Technical Data


Oil Fired Incinerator

CECON’s range of Incinerators offers you the complete solution to your waste management problem from hospitals to industrial units, CECON is the preferred choice for any type of waste management problem.

CECON INCINERATOR works on the principle of thermal destruction i.e. conversion of waste into ash by incineration at controlled temperatures. Our eco-friendly incinerators ensure total incineration with no unburnt residue and meet the emission standards laid down by the Pollution Control Board.

CECON’s unique Digital Control Panel with Digital Temperature Indicator & Controller ensures that electrical supply is automatically cut off on achieving the required temperature inside the Incineration Chamber, thus helping you save on electricity consumption.

Robust Construction
CECON INCINERATORS are constructed with Mild Steel and the body is reinforced with M.S. Angle. The body is painted with heat resistant paint. Incineration Chamber is insulated with high quality ceramic and rock wool blankets and refractory is made up of high grade Alumina and insulating bricks.

The Incinerator comprises of two chambers, with heating at Primary Chamber 850oC for burning waste and Secondary Chamber 1000oC for exhaust gas combustion.
Chimney :
The chimney is provided with Strong M.S. Base with Inspection Window and inbuilt ladder. Sampling port with sampling platform alongwith optional attachments of Aviation light, Lightning Arrestor and Earthing Strip. The Chimney is connected through centrifugal air blower for effective removal of emission from the entire system.

Venturi / Water Scrubber :
For removing impurities from the emission and waste out ash contents from the discharged air through chimney. The scrubbing is generally through water but caustic lime solution scrubbing can also be provided to neutralize any gas or acid formation.

Foul Odour Treatment Unit :
This system can effectively remove foul smell if any, generated through Bio-Medical Waste, Industrial Waste, Zoo Waste & General waste etc. This system is provided with impregnated activated charcoal filter for removing any kind of foul smell before releases through chimney.

Cyclone Dust Collector :
This system is provided to remove any solid partial from the discharged emission air. This system form a cyclonic condition and removes the particles which are collected in a tray provided with the equipment.

Droplet Separator :
This unit is provided to remove any moisture contents from the discharged emission air. This unit is attached after the water scrubber, so that the emission discharge through chimney is free from any moisture contents.

Ducting :
Internally insulated Strong flange connected with gasket is provided for inter connections of Incinerator to various pollution control accessories.


Customized – available in all sizes with accessories, starting from 5 Kg.

Convenient – Easy to install, easy to maintain and easy to use

Safe – for the operator and for the environment

Sturdy – built with MS Steel & well insulated Dual Chamber Construction

Efficient – 99% Combustion efficiency

Fuel Efficient – Economizes use of fuel and leaves no unburnt residue

Trouble Free Performance

All types of Pollution Control accessories available

Quick disposal of hazardous hospital waste

Protect environment & fight pollution by total Incineration

Eradicate Infection and contamination spreading source

Maintain clean & healthy pollution free surroundings of your Hospitals / Nursing Homes


CECON INCINERATORS are constructed with Mild Steel and the body is reinforced with M.S. Angle. The body is painted with heat resistant paint. Incineration Chamber is insulated with high quality ceramic and rock wool blankets and refractory is made up of high grade Alumina and insulating bricks.

The Incinerator comprises of two chambers, with heating at Primary Chamber 800oC±50oC for burning waste and Secondary Chamber 1050oC±50oC for exhaust gas combustion.

Export Model Incinerator : 100 Kg Capacity

Front Loading Type
A solid and sturdy unit having continuous front loading system. The Incineration Chamber is made of high quality refractory and insulation bricks and are fitted with CE Marked fully automatic burners to produce high intensity flame to dispose of any type of solid and liquid waste. The burners are operational on fuels like diesel or LPG.HSD. This unit is suitable for disposing large quantities of waste including municipal garbage, mixed hospital waste and dry, liquid Industrial waste. Available in capacity ranging from 10Kg/hr. to 500 Kg/hr.

Emission Norms
We certify that the emission discharge from CECON INCINERATORS shall be within specified limits as prescribed by Central Pollution Control Board & State Pollution Control Board.


- Conveyor Belt Arrangement

- PLC Systems for operation

- Counter Weight movement of waste charging door


- Hospital waste
- Industrial garbage
- Waste oil sludges
- Municipal waste
- House hold / Hotel’s garbage
- Infectious waste
- Security documents
- Chemical waste
- Radioactive waste
- Cytotoxic waste
- Dead Bodies / Animal Carcases

Model Capacity No. of Burners Burner Type
CTL - 10 F 10 Kg/hr. 2 Nos. Fully Automatic
CTL - 15 F 15 Kg/hr.
CTL - 20 F 20 Kg/hr.
CTL - 25 F 25 Kg/hr.
CTL - 30 F 30 Kg/hr.
CTL - 40 F 40 Kg/hr.
CTL - 50 F 50 Kg/hr.
CTL - 75 F 75 Kg/hr.
CTL - 100 F 100 Kg/hr.
CTL - 150 F 150 Kg/hr.
CTL - 200 F 200 Kg/hr. 3 Nos.
CTL - 250 F 250 Kg/hr.

Temperature
Primary Chamber : 800oC ± 50oC
Secondary Chamber : 1050oC ± 50oC

Higher Capacities are also avaliable on request.

Related Products
  • Autoclave   Autoclave
  • Crematorium   Crematorium
  • Electrical Incinerator   Electrical Incinerator
  • Needle Destroyer   Needle Destroyer
  • Sanitary Napkin Incinerator   Sanitary Napkin Incinerator
  • Animal Waste Incinerator   Animal Waste Incinerator
  • Plastic Waste Shredder   Plastic Waste Shredder

CECON POLLUTECH PVT. LTD.

5 Kamta Near Surendra Nagar Gate,
Faizabad Road, Lucknow

Ph : +91-7704003051, 7704003054

Email : cleanair@cecon.in

QUICK LINKS

About Us
Gallery
Global Installations
Privacy Policy

SOCIAL NETWORK


Contact Us
Certifications

© 2019-22 All Rights Reserved. Powered by : Skylab Engineers